AVS 72 Session TS-ThM: The Future of Temperature Sensing IV

Thursday, November 12, 2026 8:00 AM in Room 320
Thursday Morning

Session Abstract Book
(388 KB, Sep 24, 2026)
Time Period ThM Sessions | Abstract Timeline | Topic TS Sessions | Time Periods | Topics | AVS 72 Schedule

Start Invited? Item
8:00 AM Invited TS-ThM-1 Magnomechanical Noise Thermometry
John Davis (University of Alberta, Canada)

Virtually every quantum technology needs to be operated at some level of low temperatures to generate and protect low energy quantum states.As a result, cryogenics has become a critical enabling tool in the race to develop quantum technologies.Yet little attention has been paid to the thermometry that allows us to quantify these low temperatures.As an example, most users of a dilution refrigerator simply take for granted that the resistive temperature sensor they use to measure millikelvin temperatures is accurate (and actually represents their experimental temperature).A such, we believe that a renewed focus must be put on primary temperatures sensors in the sub-kelvin regime to ensure that quantum technologies and their enabling cryogenics can be accurately measured and compared between laboratories.To this end, we are working on a type of mechanical noise thermometry using the techniques of cavity optomechanics.I will provide the background and context of this temperature sensor and where we are in its development.

8:30 AM TS-ThM-3 Compact Blackbody Radiation Atomic Sensor (CoBRAS)
Eric Norrgard (National Institute of Standards & Technology); William Newman (National Institute of Standards and Technology)
The NIST Fundamental Thermodynamics group is leveraging the physical properties of atoms to provide accurate metrology of radiative temperature. Atoms are quantum systems whose interactions with electromagnetic radiation have been characterized with exquisite precision and, in many cases, are amenable to ab initio calculation. Compact Blackbody Radiation Atomic Sensor (CoBRAS) uses fluorescence detection of optically excited atoms in vapor cells to determine temperature. A CoBRAS temperature measurement is fast, with statistical uncertainty as low as 0.1% in one second. We provide an update on the temperature precision, range, and sensitivity of the CoBRAS. We also describe a new fiberized CoBRAS sensor with a form factor similar to traditional four-wire resistance thermometers.
8:45 AM TS-ThM-4 Electro-Optic Frequency Comb Doppler-Broadening Thermometry
Sean Bresler (University of Maryland, College Park/National Institute of Standards and Technology (NIST)); Erin Adkins (National Institute for Science and Technology (NIST)); Stephen Eckel (National Institute of Standards and Technology (NIST)); David Long (National Institute for Science and Technology (NIST)); Benjamin Reschovsky, Daniel Barker (National Institute of Standards and Technology (NIST))
We demonstrate Doppler-broadening thermometry based on direct optical frequency comb spectroscopy of an 85Rb vapor with a chirped electro-optic frequency comb (EOFC). The direct EOFC Doppler-broadening thermometry measurements are accurate to within their approximately K statistical uncertainty. We experimentally compare direct EOFC spectroscopy with conventional Doppler spectroscopy using a single-frequency, step-scanned laser probe. Our results show that direct EOFC spectroscopy mitigates transit-induced optical pumping distortion of the atomic lineshape, which is the dominant systematic temperature shift in alkali atom Doppler-broadening thermometry. Optical Bloch equation simulations of conventional and direct EOFC Doppler spectroscopy confirm that EOFC spectroscopy can use higher optical power to reduce statistical noise without optical pumping distortion. Our results indicate that EOFC Doppler-broadening thermometry is a promising approach to realizing a primary thermometer with size and measurement rate sufficient for applications including pharmaceutical manufacturing and nuclear waste monitoring.
9:00 AM Invited TS-ThM-5 Towards Practical Integrated Primary Thermometry with Optomechanical and Photonic Techniques
Olga Kozlova (LNE-Cnam)

Temperature is one of the most commonly measured physical quantities and influences nearly every physical, chemical, and biological process. Photonic and quantum-based approaches have the potential to transform practical thermometry by enabling in-situ traceability without requiring sensor removal for recalibration. A further advantage of these optical methods is their compatibility with silicon photonics, allowing on-chip integration thus to have the potential to radically improve thermal management of semi-conductor devices.

In this presentation, I will give an overview of the progress of European Partnership in Metrology Joint Research Project: Photonic and Quantum Sensors for Practical Integrated Primary Thermometry (PhoQuS-T) [1]. This project aims to develop integrated optical practical primary thermometry from 4 K to 500 K to enable in-situ traceability for practical applications.To achieve this, we combine several techniques: photonic thermometry using ring resonators; optomechanical noise thermometry and quantum correlation thermometry with opto-mechanical resonators. In addition, key challenges such as robust packaging over a wide temperature range are being addressed, along with metrological validation of the developed sensors and the exploration of future application possibilities.

At the current stage of the project, recent progress in photonic thermometry and optical noise thermometry from 4 K to 300 K, using 1D- and 2D- optomechanical sensors, will be presented. The next steps toward self-calibration using quantum thermometry (quantum correlation techniques [2]) will also be discussed. An overview of advances in high-resolution photonic sensors based on ring resonators operating over an extended temperature range (80 K to 500 K) will be given, along with updates on the development of a novel active thermometry approach [3]. Progress in packaging techniques (including gluing, welding, and mechanical support) for the developed sensors will also be presented.

Finally, developments toward practical application of such photonic sensors (including temperature monitoring of photonic integrated chips for optical clocks and assigning temperature in quantum-based pressure measurements) will be discussed.

References:

[1] https://www.mdpi.com/2673-8244/5/3/44

[2] https://www.science.org/doi/10.1126/science.aag1407

[3] https://doi.org/10.1098/rsta.2024.0459

9:30 AM TS-ThM-7 Two-Dimensional Silicon Optomechanical Crystals for Quantum-Referenced Temperature Sensing
Daniel Ramos (CSIC); María José Martin Hernandez (CEM); Irene Castro (CSIC); Iago Sanchez (CEM)

Accurate temperature sensing at the nanoscale remains a central challenge for emerging quantum, photonic and nanomechanical technologies, where local heating, weak thermal anchoring and limited calibration accuracy can strongly affect device performance. Optomechanical systems offer a route to temperature sensing based on the thermal occupation of mechanical modes, enabling local, contactless and potentially self-calibrated thermometry through the optical readout of mechanical motion.

Here we present the design and first experimental realization of a two-dimensional silicon optomechanical crystal engineered as a platform for temperature sensing across the transition from the classical thermal regime toward the quantum regime. The device integrates a telecom C-band optical cavity and a co-localized GHz radial-breathing mechanical mode within a two-dimensional phononic shield. This architecture combines strong optical–mechanical confinement with improved thermal anchoring to the substrate compared with conventional one-dimensional optomechanical cavities, reducing absorption-induced heating while preserving high displacement sensitivity.

The geometry was optimized using three-dimensional simulations and machine-learning-assisted parametric sweeps to achieve operation in the resolved-sideband regime, high optical and mechanical quality factors, and strong optomechanical coupling. These characteristics enable sensitive monitoring of the mechanical noise spectrum as a function of temperature and provide the basis for sideband-resolved thermometry at low phonon occupation. In this regime, the Stokes and anti-Stokes sidebands provide a direct route to absolute quantum thermometry, since their asymmetry is determined by the mean phonon population rather than by an external thermal calibration.

We discuss how this two-dimensional optomechanical platform can be used for temperature sensing from elevated temperatures down to cryogenic conditions, with particular emphasis on quantifying local optical heating, calibrating phonon occupation, and approaching the quantum ground state. By combining heterodyne sideband readout, optomechanical cooling and sideband-asymmetry thermometry, the device provides a route toward quantum-referenced nanoscale temperature sensing. These results position two-dimensional silicon optomechanical crystals as a promising integrated platform for future temperature sensors operating beyond conventional calibration limits.

9:45 AM TS-ThM-8 Multi MOF Functionalized Silicon Photonic Ring Resonator Gas Sensor with Built-in Temperature Compensation for CO2 Detection
Bibek Ramdam, Hyun-Tae Kim, Miao Yu (University of Maryland)
Metal Organic Frameworks (MOFs), a class of highly porous crystalline materials composed of metal ions linked by organic ligands [1], have found usage in applications such as hydrogen fuel storage, reversible carbon dioxide capture, and numerous gas sensing applications. However, MOF integration with photonic sensors remains a challenge. Although methods such as layer-by-layer dip coating and spin coating have demonstrated successful MOF functionalization on sensor surfaces, these methods are time consuming and are limited to just one MOF per device. In this work, we demonstrate a method for selectively functionalizing a single ring resonator device with multiple MOFs using microfluidic channels and demonstrate its CO2 sensing ability in air with any environmental fluctuations compensated for by built in temperature sensor. The two MOFs, HKUST-1 and ZIF-8, were chosen because of their simple fabrication process and prevalence in literature. The device consists of four silicon ring resonators coupled to a single bus waveguide. One ring is functionalized with HKUST-1, and the second is functionalized with ZIF-8; these are the two rings used for detecting CO2 in air. A third ring, which is unexposed, was left covered with SiO2 and serves as an integrated temperature sensor for temperature compensation. The entire device is encapsulated in polydimethylsiloxane (PDMS) which protects the underlying MOF layers. This leaves the fourth ring, which is simply covered by PDMS and could be functionalized with a different MOF in the future. The temperature ring demonstrated a sensitivity of 39 pm/oC, while the ZIF-8 coated ring exhibited a sensitivity of 0.170 pm/% vol. of CO2 whereas HKUST-1 coated ring had a sensitivity of -0.232 pm/% vol. of CO2. Interestingly, the sensitivities offered by the ZIF-8 and HKUST-1 coated rings were opposite in direction, highlighting their distinct chemical interaction with CO2. The fabrication technique reported in this work provides a versatile platform for integrating multiple MOFs in a single photonic chip, paving the way to revolutionize gas sensing technologies by enabling customizable sensors tailored to specific applications.

Acknowledgements

This work was financially supported by NSF GCR (grant numbers: OIA2121110 and OCE2322282).

References

[1] H Furukawa et al., Science (2013) 341, 6149.
10:00 AM BREAK - Complimentary Coffee in Exhibit Hall
Session Abstract Book
(388 KB, Sep 24, 2026)
Time Period ThM Sessions | Abstract Timeline | Topic TS Sessions | Time Periods | Topics | AVS 72 Schedule